  • The Circutor Computer SMART III 14 (code R13864) is a three-phase automatic power factor regulator that manages reactive energy compensation across 14 contactor-switched steps. It accepts an AC supply of 100…400 V at 50…60 Hz and communicates via RS-485 using the Modbus RTU protocol, making it a capable choice for both new installations and regulator replacements in industrial compensation panels.

    Technical specifications:

    • Model: Computer SMART III 14
    • Circutor code: R13864
    • EAN: 8433059227494
    • Type: Three-phase power factor regulator
    • Number of regulation steps: 14
    • Switching unit: Contactor
    • AC power supply: 100…400 V AC, 50…60 Hz
    • Power consumption: 14…18 VA
    • Voltage measurement range: 20…300 V Ph-N / 35…520 V Ph-Ph
    • Nominal voltage: 230 V Ph-N / 400 V Ph-Ph
    • Minimum measurement voltage: 20 V Ph-N / 35 V Ph-Ph
    • Input current: …/5 A or …/1 A
    • Phase current measuring range: 1…120% of nominal
    • Minimum current measurement: 50 mA
    • Serial communication: RS-485, Modbus RTU
    • Digital relay outputs: 16 total (14 step outputs, 1 fan, 1 alarm relay)
    • Relay output ratings: 1 A, 1 kV max open-contact voltage, 2500 VA max switching capacity
    • Relay electrical life: 30 x 10^3 cycles; mechanical life: 5 x 10^6 cycles
    • Digital transistor outputs: 2 x NPN, 50 mA, 24 V DC
    • Digital inputs: 2, optoisolated, potential-free contact
    • Leakage current measurement range: 0.01…1.5 A
    • Active power measurement accuracy: 0.5% +/- 1 digit
    • Reactive power measurement accuracy: 1% +/- 2 digits, Class 1
    • Active energy accuracy: 0.5% +/- 2 digits
    • Reactive energy accuracy: Class 1
    • Phase current accuracy: 0.5% +/- 1 digit
    • Installation category: CAT III 300 V
    • Protection class: IP 51 (front panel) / IP 31 (unmounted)
    • Dimensions (W x H x D): 144 x 144 x 71 mm
    • Mounting: Panel
    • Weight: 0.619 kg
    • Operating temperature: -10…+55 C
    • Storage temperature: -20…+70 C
    • Relative humidity: 5…95% (non-condensing)
    • Display: LCD custom COG
    • Interface: Capacitive keyboard (5 keys), 4 LED indicators
    • Maximum installation altitude: 2000 m
    • Standards: IEC 61010, IEC 61000-6-2, IEC 61000-6-4, IEC 61557-12

    Features and benefits:

    • Supports measurement with either one or three current transformers, allowing the regulator to mirror the utility meter reading precisely and handle installations where phase currents are significantly unbalanced.
    • Residual leakage current monitoring is available when used with compatible WG-series current transformers, adding an extra layer of safety supervision within the compensation panel.
    • RS-485 Modbus RTU communication enables integration with SCADA systems, energy management platforms, or building automation networks for centralised monitoring.
    • Up to four programmable cos phi target values can be set to match different tariff time periods, reducing manual intervention when consumption patterns change throughout the day.
    • The wide AC supply range of 100…400 V and voltage measurement span up to 520 V Ph-Ph make the unit suitable for diverse grid conditions without requiring additional matching transformers.

    Applications:

    • Automatic reactive energy compensation in industrial plants, manufacturing facilities, and large commercial buildings to reduce reactive energy penalties.
    • Retrofitting or upgrading the controller in existing capacitor banks where a drop-in regulator replacement is required.
    • Installations with pronounced phase current imbalances where three-transformer measurement delivers greater compensation accuracy than a single-CT setup.
    • Medium voltage compensation systems that require a regulator capable of operating across a broad voltage measurement range.

    Also known as: Circutor Computer SMART III 14, Computer SMART III 14 R13864, R13864 power factor controller, Circutor reactive energy regulator, three-phase power factor regulator 14-step.