  • The Schneider Electric LADR0 is an off-delay time delay auxiliary contact block from the TeSys Deca range. It provides a 1 NO + 1 NC contact arrangement with an adjustable delay of 0.3 to 3 seconds at up to 690 V AC, and mounts on the front of TeSys Deca CAD, LC1D, and TeSys F LC1F and CR1F contactors.

    Technical specifications:

    • Commercial reference: LADR0
    • Manufacturer: Schneider Electric
    • EAN: 3389110386141
    • Series / range: TeSys Deca
    • Product type: Time delay auxiliary contact block
    • Contact arrangement: 1 NO + 1 NC
    • Timer type: Off-delay
    • Time delay range: 0.3…3 s
    • Rated operational voltage [Ue]: 690 V AC (25…400 Hz)
    • Rated current [Ie]: 6 A at 120 V AC-15; 1.04 A at 690 V AC-15
    • Rated insulation voltage [Ui]: 690 V per IEC 60947-5-1
    • Permissible thermal current [Ith]: 10 A at 60C
    • Mechanical endurance: 5 million cycles
    • Connection type: Screw terminals, 1…2.5 mm
    • Mounting location: Front
    • Dimensions (WxHxD): 44 x 48 x 61 mm
    • IP protection rating: IP20 per IEC 60529
    • Operating temperature: -40…70C
    • Certifications: IECEE CB, UL, CSA, CCC, EAC, UKCA

    Features and benefits:

    • Adjustable off-delay of 0.3 to 3 s for precise timing in motor and load control circuits
    • Wide operating range of -40 to 70C suited to demanding industrial environments
    • 1.5 ms non-overlap time between NC and NO contacts ensures clean, fault-free switching transitions
    • 5 million mechanical cycles for long service life in high-frequency switching applications
    • Screw terminals accept 1…2.5 mm flexible and rigid cables for flexible panel wiring

    Applications:

    • Motor control panels requiring off-delay timing for controlled stop or sequenced switching
    • Industrial automation systems using TeSys LC1D or TeSys F LC1F contactors with timed auxiliary logic
    • Machine control circuits needing time-delayed interlocking between NC and NO outputs
    • HVAC and air conditioning control panels conforming to IEC 60335-2-40

    Compliant with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and EN 50012. Part of the Schneider Electric TeSys Deca range.